TcoInspectors

API

Inspectors provide mechanisms for checking the different types of data. Inspector compares input data with the required value. In addition to a simple comparison of values, the inspector provides stabilization timing and timeout for failed inspection. Inspectors can integrate with coordination primitives like TcoSequencer that offer extended capabilities in decision flow for failed checks.

General

API

Data

Basic settings

image

Common inspector details image

Inspector types

TcoDigitalInspector

API

Data

Inspector provides evaluation of discrete value. The input value compares against the Required value. The inspection passes when the input value matches the required value without interruption for the duration of stabilization time.

TcoAnalogueInspector

API

Data

Provides evaluation of continuous values. The inspector checks that the input value falls within the limit of Min and Max. The inspection passes when the input value is within the required limit without interruption for the duration of stabilization time.

TcoDataInspector

API

Data

Provides evaluation of alphanumerical values. The input value compares against the Required value. The inspection passes when the input value matches the required value without interruption for the duration of stabilization time. In addition to exact comparison, data inspector allows for simple pattern matching where # = any number and * = any character.

Preserving overall result

Overall result of a series of inspections can be preserved in TcoComprehensiveResult. Each inspector has UpdateComprehensiveResult method that provides the update function. Once UpdateComprehensiveResult marks the overall result as Failed, successive inspection will not overwrite the result.

Handling failure

When an inspector fails, OnFail() provides a series of methods for making decisions about the process. In order for this is feature to work the inspector needs to be aware of the coordinator of ITcoCoordinator (e.g. sequencer). The coordinator must be passed to the inspector by WithCoordinator(coordinator) method.

Method Description
Dialog(RetryState) Opens dialog for the user to take a decision. Retry state parameter tells from which state the inspection should start again.
Retry(RetryState) Retries the inspector. Retry state parameter tells from which state the inspection should start again. When the parameter Retries is set (non zero), the inspection will run only a given number of times; if the inspection does not succeeds the it will continue with the failed result. 0 value of retries indicates no limit to the number of tests.
Override() Marks the inspection as failed but continues with the following states of the coordinator.
Terminate() Marks the inspection as failed and aborts the execution of the coordinator. (recovery step or returns to the beginning of the sequence)

Single inspector with Dialog in case of failure

image
IF (seq.Step(inStepID := 100,
    inEnabled := TRUE,
    inStepDescription := 'INSPECT DMC CODE')) THEN
    //--------------------------------------------------------
    Data.DmcInspector.WithCoordinator(seq)              // Coordinator                     
        .Inspect(Components.DmcReader)                  // Inspection input
        .UpdateComprehensiveResult(Data.OverallResult)  // Updated overall result
        .OnFail()                                       // Selector what should happen when inspection fails
        .Dialog(50);                                    // On failure dialogue is displayed for the operator to take decision    
    //--------------------------------------------------------          
END_IF;

Single inspector with CarryOn in case of failure

IF (seq.Step(inStepID := 100,
    inEnabled := TRUE,
    inStepDescription := 'INSPECT DMC CODE')) THEN
    //--------------------------------------------------------
    Data.DmcInspector.WithCoordinator(seq)              // Coordinator                     
        .Inspect(Components.DmcReader)                  // Inspection input
        .UpdateComprehensiveResult(Data.OverallResult)  // Updated overall result
        .OnFail()                                       // Selector what should happen when inspection fails
        .CarryOn();                                   // On failure sets overall result to fails but continues with in the sequence
    //--------------------------------------------------------          
END_IF;

Single inspector with Terminate in case of failure

IF (seq.Step(inStepID := 100,
    inEnabled := TRUE,
    inStepDescription := 'INSPECT DMC CODE')) THEN
    //--------------------------------------------------------
    Data.DmcInspector.WithCoordinator(seq)              // Coordinator                     
        .Inspect(Components.DmcReader)                  // Inspection input
        .UpdateComprehensiveResult(Data.OverallResult)  // Updated overall result
        .OnFail()                                       // Selector what should happen when inspection fails
        .Terminate();                                   // On failure sets overall result to fails and terminates the sequence
    //--------------------------------------------------------          
END_IF;

Single inspector with Retry in case of failure

IF (seq.Step(inStepID := 100,
    inEnabled := TRUE,
    inStepDescription := 'INSPECT DMC CODE')) THEN
    //--------------------------------------------------------
    Data.DmcInspector.WithCoordinator(seq)              // Coordinator                     
        .Inspect(Components.DmcReader)                  // Inspection input
        .UpdateComprehensiveResult(Data.OverallResult)  // Updated overall result
        .OnFail()                                       // Selector what should happen when inspection fails
        .Retry(50);                                     // On failure retries the check until succeds.
    //--------------------------------------------------------          
END_IF;

Evaluating multiple inspectors at once

Multiple inspectors with Dialog in case of failure

image
VAR
    // Helper for evaluation of multiple inspectors
    Eval : TcoInspectors.TcoInspectionGroup(THIS^);
END_VAR
//---------------------------------------------------------

IF MS.Step(Uid := 260, 
           Enabled := TRUE, 
           HmiMessage := '<#KONTROLA SPRAVNEHO PRIPRAVKU#>') THEN
//--------------------------------------------------------------        
    Eval.WithCoordinator(MS)                                                // Tells which coordinator (sequencer) is used
        .Act()                                                              // Make inspections available
        .Inspect(ProcessData.Data.Cu1.LogicCheck.Inspect(FALSE))            // Inspectors 
        .Inspect(ProcessData.Data.Cu1.LogicCheck1.Inspect(FALSE))
        .Inspect(ProcessData.Data.Cu1.LogicCheck1.Inspect(FALSE))
        .UpdateComprehensiveResult(ProcessData.Data.EntityHeader.Results)   // Update global result
        .OnFail()                                                           // Selection of action in case of failure
        .Dialog(260);                                                       // Shows dialogue
//--------------------------------------------------------------    
END_IF

Multiple inspectors with CarryOn in case of failure

VAR
    // Helper for evaluation of multiple inspectors
    Eval : TcoInspectors.TcoInspectionGroup(THIS^);
END_VAR
//---------------------------------------------------------

IF MS.Step(Uid := 260, 
           Enabled := TRUE, 
           HmiMessage := '<#KONTROLA SPRAVNEHO PRIPRAVKU#>') THEN
//--------------------------------------------------------------        
    Eval.WithCoordinator(MS)                                                // Tells which coordinator (sequencer) is used
        .Act()                                                              // Make inspections available
        .Inspect(ProcessData.Data.Cu1.LogicCheck.Inspect(FALSE))            // Inspectors 
        .Inspect(ProcessData.Data.Cu1.LogicCheck1.Inspect(FALSE))
        .Inspect(ProcessData.Data.Cu1.LogicCheck1.Inspect(FALSE))
        .UpdateComprehensiveResult(ProcessData.Data.EntityHeader.Results)   // Update global result
        .OnFail()                                                           // Selection of action in case of failure
        .CarryOn();                                                         // Marks as failed but continues go ahead
//--------------------------------------------------------------    
END_IF

Multiple inspectors with Terminate in case of failure

VAR
    // Helper for evaluation of multiple inspectors
    Eval : TcoInspectors.TcoInspectionGroup(THIS^);
END_VAR
//---------------------------------------------------------

IF MS.Step(Uid := 260, 
           Enabled := TRUE, 
           HmiMessage := '<#KONTROLA SPRAVNEHO PRIPRAVKU#>') THEN
//--------------------------------------------------------------        
    Eval.WithCoordinator(MS)                                                // Tells which coordinator (sequencer) is used
        .Act()                                                              // Make inspections available
        .Inspect(ProcessData.Data.Cu1.LogicCheck.Inspect(FALSE))            // Inspectors 
        .Inspect(ProcessData.Data.Cu1.LogicCheck1.Inspect(FALSE))
        .Inspect(ProcessData.Data.Cu1.LogicCheck1.Inspect(FALSE))
        .UpdateComprehensiveResult(ProcessData.Data.EntityHeader.Results)   // Update global result
        .OnFail()                                                           // Selection of action in case of failure
        .Terminate();                                                       // Marks as failed and abandons the sequence
//--------------------------------------------------------------    
END_IF

Multiple inspectors with Retry in case of failure

VAR
    // Helper for evaluation of multiple inspectors
    Eval : TcoInspectors.TcoInspectionGroup(THIS^);
END_VAR
//---------------------------------------------------------

IF MS.Step(Uid := 260, 
           Enabled := TRUE, 
           HmiMessage := '<#KONTROLA SPRAVNEHO PRIPRAVKU#>') THEN
//--------------------------------------------------------------        
    Eval.WithCoordinator(MS)                                                // Tells which coordinator (sequencer) is used
        .Act()                                                              // Make inspections available
        .Inspect(ProcessData.Data.Cu1.LogicCheck.Inspect(FALSE))            // Inspectors 
        .Inspect(ProcessData.Data.Cu1.LogicCheck1.Inspect(FALSE))
        .Inspect(ProcessData.Data.Cu1.LogicCheck1.Inspect(FALSE))
        .UpdateComprehensiveResult(ProcessData.Data.EntityHeader.Results)   // Update global result
        .OnFail()                                                           // Selection of action in case of failure
        .Retry(200);                                                        // Tries again the inspection from the given step UID
//--------------------------------------------------------------    
END_IF